Production servers, populated data center racks, broadcast and pro A/V gear, 98-inch displays, semiconductor wafers and tools, photonics, lab instrumentation. Vibration-sensitive, ESD-sensitive, climate-sensitive, and high-value. Built for IT operators, integrators, manufacturers, and enterprise shippers.
📞 Get Electronics Rate: (786) 574-5774 ✉ rates@ship-ati.com| Tier | Equipment | Handling |
|---|---|---|
| Standard LTL | Packaged consumer goods, retail freight, reels of cable | Standard pallet/box, dock-to-dock |
| Air-Ride | Production servers, broadcast and pro A/V, lab instrumentation | Air-ride trailer, vibration log, white-glove available |
| Climate + Air-Ride | OLED panels, optics, biotech instruments, calibrated test equipment | Climate-controlled 60–75°F, air-ride, temp log |
| ESD Protected | Semiconductor wafers/tools, bare PCBs, photonics, populated racks | Static-dissipative materials, grounded handling, humidity control |
| Crated Specialty | Large-format displays, projection equipment, art-installation displays | Custom crate, vertical-only, white-glove install |
Data center migrations are a category of their own. ATI moves single servers, full populated racks, networking equipment, storage arrays, and UPS infrastructure across metro, regional, and nationwide lanes for enterprises, colo customers, MSPs, and federal contractors.
UPS battery strings are lithium-ion or sealed lead-acid. Lithium-ion shipped installed in functional equipment ships under Section II of 49 CFR 173.185, which allows transport with reduced documentation provided cells pass UN 38.3 testing and are protected from short-circuit. Sealed lead-acid (VRLA) batteries fall under 49 CFR 173.159a and ship as non-spillable wet batteries with appropriate marking. Loose UPS batteries shipped separately from equipment ship as Class 9 hazmat with full UN identification and shipping papers. See our hazmat freight shipping guide for the documentation details.
Tour-grade audio, broadcast cameras, video walls, projection equipment, lighting rigs — common shipments for AV integrators, production companies, esports venues, churches, and live event organizations. The combination is high value, vibration-sensitive, and frequently time-critical (a show is a show; freight has to land on the install day, not three days late).
ATI’s pro A/V capacity is air-ride straight truck or trailer with white-glove inside delivery. For tour-grade equipment we coordinate with case manufacturers’ standard road-case provisions; for fixed-install equipment we typically crate at origin.
Air-ride · ESD · Climate · White-glove install
TVs and digital signage panels over 75 inches are panel-fragile in ways smaller TVs aren’t. Three handling rules apply:
White-glove inside delivery is standard for these. The team brings the display in vertical, places it on a stand or wall mount, and confirms power-up. Wall mounting on drywall is a premium add-on requiring stud-finder verification and appropriate fasteners.
Fab tool moves, mask aligners, wafer steppers, lithography systems, deposition equipment, metrology tools — semiconductor industry equipment ranks among the most demanding specialty freight in the world. ATI’s semiconductor freight runs under air-ride, climate-controlled, ESD-protected, and shock-monitored protocols with continuous data logging. Engineering coordination with the OEM service team is mandatory; un-shipped or post-ship recalibration runs into six figures.
Photonics — lasers, optical benches, fiber assemblies, spectrometers — ship under similar protocols at smaller scale. Climate stability protects optical alignment; vibration control protects mirror and lens positioning.
Mass spectrometers, calibrated test instruments, gas chromatographs, environmental chambers, and similar lab gear sit at the intersection of medical equipment and electronics freight. See the medical equipment freight guide for the broader clinical and biotech context; the same air-ride + climate + condition-report protocols apply.
| Shipment | Typical Range |
|---|---|
| Single server (rack-mount, packaged) | $180–$650 |
| Populated 42U rack (regional) | $1,800–$4,500 |
| Populated 42U rack (nationwide) | $3,500–$8,500 |
| 98-inch display (crated, white-glove) | $1,200–$3,800 |
| Broadcast camera package (regional) | $650–$1,900 |
| Semiconductor tool relocation | $25,000–$250,000+ |
| Data center migration (10-rack) | $45,000–$180,000 |
Need NMFC class for accompanying freight? Use the ATI freight class calculator.
ATI coordinates specialty electronics freight nationwide on air-ride, climate-controlled, and ESD-protected capacity. Enterprise IT operations, colocation customers, AV integrators, broadcast organizations, semiconductor manufacturers, and lab instrument OEMs use ATI for moves where commodity freight isn’t an option.
Call (786) 574-5774 or email rates@ship-ati.com.
Air-ride. ESD. Climate. White-glove. Nationwide. Production-grade.